Standard PSI Pressure Transducers
Pressure Transducer Measures 0-30 PSI, 0-50 PSI, 0-60 PSI, 0-100 PSI, 0-150 PSI, 0-200 PSI, and 0-500 PSI
Click here for -14.5 to 10000 PSI pressure transducers
Not all pressure transducers are built the same, click here to find out more before you order!
Select Range:
Measures 0-30 PSI
Stock
- Measure pressure from 0-30 to 0-500 PSI. Click here for -14.5 to 10000 PSI pressure transducers
- Compatible data acquisition devices
- Made with 316 stainless steel and high temperature auto-graded plastic
- 0.5V – 4.5V linear voltage output. Click here for 4-20mA output pressure transducers
- Ceremic sensor accuracy ±2%FS.
- Works for oil, fuel, brake fluid, water or air pressure
- Mating connector and wire harness (3 ft pigtail) included
- IP67 Rated (protection against dust and temporary water immersion to 1m depth)
- Compatible with many Dataq Instruments hardware products including DI-2108, DI-2108-P, DI-4108, DI-4208, DI-4718B (with appropriate 8B module), and DI-2008/808 (with 15V to 5V DC2DC).
- Learn how to connect and measure PSI with this pressure sensor
Description
The Pressure sensor measures 0-15 up to 0-500 PSI when connected to a Dataq Instruments Data Acquisition product or Data Logger.
The pressure sensor allows Dataq Instruments data acquisition and data logger units to acquire oil, fuel, air, brake fluid (DOT3/DOT4) or water pressure (PSI) information. The combination of these two products provides a compact solution, with transducer excitation provided by the data logger. The logger itself allows data to be communicated to a connected PC over either a USB or Ethernet interface. Optionally, many data loggers can store data to a removable USB thumb drive to satisfy stand-alone applications. Even with a connected pressure sensor, the data logger channel capacity allows additional channels of information to be acquired and correlated with pressure information to satisfy nearly any level of measurement expansion.
Not all pressure transducers are built the same
The diaphgram of pressure transducers can employ different material and technologies, and each one has its pros and cons. Here is the quick comparison table among the two types we offer
Product lines | 2000361-H (0.5-4.5V output) 2000361-HX (4-20mA output) 2000361-CH (Customized model) |
2000361 |
Material/Technologies | Oil-filled diffusion silicon piezoresistive | Dry ceramic capactitive Not recommended for strong EMI environment |
Output | 2000361-H: 0.5-4.5V 2000361-HX: 4-20mA 2000361-CH: 0.5-4.5V or 4-20mA |
0.5-4.5V |
Pressure Type | Gauge pressure Customization to Absolute pressure is available |
Gauge pressure |
Accuracy/Sensitivity | ±0.5%FS * Ranges lower than +5 PSI has 0.5-1% accuracy |
±2% FS |
Medium | Any gas or liquid compatible with 316L stainless steel (Not intended for acidic medium) |
Any gas or liquid compatible with ceramic |
Burst Pressure | For transducers of full range up to 5000 PSI, 4 times span For transducers of full range of 10000 PSI, 26000 PSI |
4 times span |
Overload Pressure | For transducers of full range up to 5000 PSI, 2.5 times span For transducers of full range of 10000 PSI, 14500 PSI |
2.5 times span |
Response Time | 1ms | 1ms |
Working Temperture Range | -40°C to 85°C | -20°C to 70°C |
Insulation Resistance | 100ma 500VDC | 100ma 500VDC |
3D Model | 1/4 NPT version | |
Process Connection (Thread) | 1/4" NPT-18 thread for 10000 psi 1/8" NPT-27 thread for the others (1/4 NPT" pipe fitting can be found here) |
1/8" NPT-27 thread (1/4" NPT pipe fitting can be found here) |
Electromagnetism Compatibility | EN61326-1:2013 EN61326-2-2:2013 The EMC Directive2014/30/EU |
EN61326-1:2013 EN61326-2-2:2013 The EMC Directive2014/30/EU |
Supply Voltage | 4.75-5.25V for 2000361-H (0.5-4.5V output model) 8-30V for 2000361-HX (4-20mA output model) |
4.75-5.25V |
Max Power Consumption | 0.05W for 2000361-H (0.5-4.5V output model) |
0.05W |
Sealing Material | NBR rubber |
NBR rubber |
Included Wiring Harness | 3 ft (10ft harness can be found here) | 3 ft (10ft harness can be found here) |
Standard Ranges | -14.5 to 15, 30 psi 0 to -14.5, 15, 30, 50, 60, 100, 150, 200, 300, 500, 1000,
1500, 2000, 3000, 5000, 10000 psi |
0 to 30, 50, 60, 100, 150, 200, 500 psi |
Customized Ranges | -14.5 psi to 10000 psi | NA |
Cost | $
68
for 2000361-H (0.5-4.5V output model) $ 79 for 2000361-HX (4-20mA output model, 250 Ohm shunt resistor included) $ 99 for 2000361-CH (Typical lead time, 8 weeks) |
$ 39.99 |
Accessories
Description
Allows you to power 5V rating sensor with a battery. Input voltage: DC8-35V, (12V/24V changes to 5V); Output parameter: DC5V 3A, 15W MAX
Description
10-foot long wire harness (pigtail) with mating connector and seal for pressure transducers
Description
Spare 3-foot long wire harness (pigtail) with mating connector and seal for pressure transducers
Description
To convert pressure transducer fitting from 1/8 NPT to 1/4 MNPT
Max operating pressure: 2000 PSI
Specifications
Measurement Range: | 2000361-30: 0 to 30 PSI 2000361-50: 0 to 50 PSI 2000361-60: 0 to 60 PSI 2000361-100: 0 to 100 PSI 2000361-150: 0 to 150 PSI 2000361-200: 0 to 200 PSI 2000361-500: 0 to 500 PSI |
Material: | 316 stainless steel and high temperature auto-graded plastic |
Output: | 0.5V – 4.5V linear voltage output |
Supply Voltage: | 5V +/-5%, 0.02W |
Long Term Working Temperature: | -20°C to 70°C |
Accuracy: | ±2%FS for ceramic pressure transducers. |
Thread: | 1/8” NPT-27 |
Protection Class: | Typical IP65-66, depending on electric connection. |
Overload Capacity: | 2 times. |
Pressure Medium: | Any gas or liquid compatible with 316L stainless steel |
Long-term stability: | ± 0.5%FS/year |
Response Time: | ≤1ms |
Insulation Resistance: | >100mΩ 500VDC |
Electromagnetism Compatibility: | EN61326-1-2013 EN61325-2-2:2013 EMC Directive 2014/30/EU |
Wiring connector: | Water sealed quick-disconnect. Mating connector and wire harness (3 ft pigtail) included. |
Wiring: | Red for +5V Supply Voltage Black for GND Yellow or Green for OUT |
Warranty: | 90 days |
Logger inaccuracy not included in these specifications.
Articles
Making Pressure Measurements with the DI-1100 Starter Kit
Making Pressure Measurements with a Dataq Data Logger and Pressure Sensor