Site Search:

Model EL-GFX-DTP+

High Accuracy Graphing Dual-channel Thermistor Data Logger - Probes measure -40 to +125°C (-40 to +257°F)

$302.99
In
Stock
  • Includes an EL-GFX-DTP+ data logger, a 31-inch USB cable, a mounting clip, two batteries (pre-installed), 2 high accuracy thermistor probes, and downloadable software (CALIBRATION CERTIFICATE sold separately under ACCESSORIES tab and must be ordered at time of purchase)
  • Dual thermistor inputs measure -40 to +125°C (-40 to +257°F)
  • Stand-alone operation with a USB interface for configuration and upload
  • Sample intervals from 2s to 1hr
  • Stores up to 250,000 readings
  • Programmable high and low alarms with audio/visual alerts
  • High contrast LCD display
  • Downloadable EL-Win-USB software for set-up and data analysis
  • Powered by replaceable ½AA long-life lithium batteries (2)
  • Quantity Discount
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
EL-GFX-DTP Data Logger
This data logger has 0.1 degree of resolution.This data logger has two input channels.This data logger measures temperature.This data logger measures temperatures from -40 to +125°C (-40 to +257°F).This data logger can record one sample every 2 seconds.
This data logger has a USB interface.This data logger records data to internal memory.Get same day shipping when you order this data logger before 3PM ETThis data acquisition system has a 30-day Money back guaranteeUse coupon code EL10USB for 10% off your Lascar data logger purchase.

Description

The EL-GFX-DTP+ is a high accuracy dual-channel temperature data logger, capable of displaying and logging data from two thermistors, simultaneously. The stand alone logger includes two 1 meter thermistors with a -40 to +125°C (-40 to +257°F) measurement range. With sample intervals ranging from 2 seconds to 1 hour, the EL-GFX-DTP+ has the capacity to store up to 250,000 readings. Programmable alarms for each thermistor channel allow you to illuminate a LED and/or trigger a sound when temperatures rise above or fall below specified levels.

Three control buttons allow you to start and stop recording, view alarm levels and perform basic data analysis. You can view minimum and maximum values or graph data in real-time on the high contrast LCD display.

The downloadable EL-WIN-USB software allows you to configure the EL-GFX-DTP for single or dual channel operation, choose a Thermistor type and select a sample interval. In addition, alarm levels can be set and audio/visual alarm indicators can be configured. The EL-WIN-USB software also programs the EL-GFX-DTP for when to begin recording data; whether at a specific date and time, at a particular temperature threshold, or as soon as the logger is disconnected from the USB port.

Accessories

BAT 3V6

3.6V Battery

$5.99
Lascar Data Logger Battery

Description

Replacement 3.6V, 1200mAh lithium battery. Two (2) required for use with this data logger. Please Note: Continental U.S. shipping ONLY.

EL-PROBEEXTENDER-5M

Thermistor Extender

$11.99
Probe Extender

Description

5 meter thermistor probe extender. 3.5 mm jack extender.

EL-PROBEEXTENDER-10M

Thermistor Extender

$13.99
Probe Extender

Description

10 meter thermistor probe extender. 3.5 mm jack extender.

EL-P-VAC

Temperature Probe

$37.99
Glycol Probe

Description

High accuracy temperature probe, designed to mimic a product's temperature response. -40 to 125°C (-40 to 257°F) measurement range; Accuracy of ±0.1ºC (-10 to 70°C), ±0.3ºC (-40 to 125°C); 40 minute T90 response (Based on response to a step temperature change of -10 to 21°C).

EL-P-TP+

Thermistor Probe

$32.99
Temperature Probe

Description

Spare high accuracy thermistor probe for EL..TP+ products. -40 to 125°C (-40 to 257°F) measurement range; Accuracy of ±0.1°C (-10 to 70°C), ±0.3°C (-40 to 125°C); 75mm stainless steel capped probe on 3m cable.

CAL EL-USB-TEMP-1

Calibration Certificate (1st Cal Value)

$40.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase this first point option first for each device, and then additional points per device as required. Standard points are $40. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

CAL EL-USB-TEMP-2

Calibration Certificate (2nd Cal Value)

$25.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase the first point option first (CAL EL-USB-TEMP-1) for each device, and then additional points per device as required. Standard points are $25. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

Software

EasyLog Software

Configuration Software

FREE Configuration and download software for Lascar Data Loggers.

Lascar EasyLog Software

Specifications

Number of Channels: Two
Supplied probe measurement range: -40 to +125°C (-40 to +257°F)
Internal Resolution: 0.1°
Accuracy (overall error): ±0.1°C (±0.2°F)
At 25°C. See probe accuracy curve on datasheet.
Important - quoted accuracy is for the data logger only when measuring within the specified operating temperature.
Thermistor error is not included and should also be taken into consideration.
Logging Rate: 1 sample every 2 seconds
1 sample every 5 seconds
1 sample every 10 seconds
1 sample every 15 seconds
1 sample every 20 seconds
1 sample every 30 seconds
1 sample every 1 minute
1 sample every 2 minutes
1 sample every 5 minutes
1 sample every 10 minutes
1 sample every 15 minutes
1 sample every 20 minutes
1 sample every 30 minutes
1 sample every 1 hour
Memory Capacity: 250,000 samples
Operating Temperature Range: -10 to +40°C (-14 to +104°F)
(Operating temperature applies to the data logger module only. Please consult the probe manufacturer for operating temperature of thermocouple.)
Battery Life 4 months
(at 25°C and 10 minute logging rate with no alarm LEDs or sounder and minimal LCD use)

Articles

EL Data Logger Series and Calibration Certificates (blog post)

Go to the Support Forum

Submit a Support Ticket

Videos

EasyLog Software
EasyLog Setup

Learn how to set up Lascar Data Loggers with EasyLog Software.

Similar Products

Reviews