Model EL-SIE-2+

High Accuracy USB Data Logger Measures Temperatures from -18 to +55°C (-0.4 to +131°F) and 0 to 100%RH

$156.49
In
Stock
  • Includes an EL-SIE-2+ USB data logger, a wall mounting bracket, 2 × 1.5V AAA batteries, and a USB A to USB C cable (CALIBRATION CERTIFICATE sold separately under ACCESSORIES tab and must be ordered at time of purchase)
  • Measures ambient temperature between -18 to +55 °C (-0.4 to +131 °F)
  • Measures relative humidity 0 to 100%
  • Dew point calculation
  • Records up to 1,000,000 data points to internal memory
  • Export data to .csv file or upload to EasyLog Cloud
  • Measurement accuracy of ±0.2°C (±0.36°F) typical
  • Access live temperature data using any Browser software
  • Status and alarm indicators
  • IPX4 rating - protected from splashing water, no matter the direction
  • Battery life more than 1 year (at 25°C with 10 minute logging rate)
  • Logging rates from 1 sample every 10 seconds to 1 sample every 24 hours
  • Quantity Discount
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
EL-SIE-1 Data Logger
This data logger has 0.01 degree of resolution.This data logger has a single channel.This data logger measures temperature and humidity.This data logger measures temperatures from -18 to +55°C (-0.4 to +131 °F).This data logger can record one sample every 10 seconds.
This data logger has a USB interface.This data logger records data to internal memory.This data logger records data to the cloud.
Get same day shipping when you order this data logger before 3PM ETThis data acquisition system has a 30-day Money back guaranteeUse coupon code EL10USB for 10% off your Lascar data logger purchase.

Description

The EL-SIE-2+ kit is designed to monitor ambient temperature and humidity in a large range of applications, and is suitable for monitoring environments such as residential spaces, offices, warehousing, building management, logistics, clean rooms, and greenhouses.

Products in the EL-SIE range are simple to set-up and easy to use. No software is required other than an internet browser (does not require an internet connection). Use the supplied USB-A to USB-C cable to connect to your computer under any operating system (MAC, PC, etc).

Set a logging interval between 10 seconds and 24 hours, with immediate, delayed, triggered or push-to-start logging. Alarms are fully user configurable, with functionality including cumulative alarms, pre-alarms, a delay before alarm triggering, and an alarm hold option, which continues showing the alarm condition even if the reading returns to an acceptable level.

The LCD display shows current, maximum and minimum readings, and three coloured LEDs indicate device status at a glance. Once logging is complete, re-connect to your computer and use your browser to view, analyse and save your data. You can also choose to upload your data to an Easy Log Cloud account, making the data accessible online for powerful graphing, analysis and report generation.

Accessories

CAL EL-USB-TEMP/RH-1

Calibration Certificate (1st Cal Value)

$90.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post Lascar Data Logger Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase this first point option first for each device, and then additional points per device as required. Standard points are $90. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

CAL EL-USB-TEMP/RH-2

Calibration Certificate (2nd Cal Value)

$25.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post Lascar Data Logger Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase the first point option first (CAL EL-USB-TEMP/RH-1) for each device, and then additional points per device as required. Standard points are $25. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

Software

No software required other than a web browser (for example, Chrome, IE, Edge, Safari, etc.)

Specifications

Number of Channels: One, measures temperature and humidity
Temperature Measurement Range: -18 to +55°C (-0.4 to +131°F)
Temperature Measurement Resolution: 0.01°
Temperature Measurement Accuracy: ±0.2°C (±0.36°F) typical
Temperature Long term stability: <0.03°C (<0.054°F) / year
Humidity Measurement Range: 0 to 100%RH
Humidity Resolution: 0.1%RH
Humidity Accuracy: ±1.5% typical (0 to 80%RH)
Humidity Long term stability: <0.25%RH / year typical
Dew Point Accuracy: 1.5°C typical (40 to 100%RH)
Logging Rate: 1 sample every 10 seconds to 1 sample every 24 hours
Start Modes: Immediate, push to start, triggered start, parameter triggered
Memory capacity: Over 1,000,000 total readings
Operating Temperature Range: -18 to +55°C (-0.4 to +131°F)
Battery Life: >1 year at 25°C with 10 minut logging rate
Battery Type: 2 × 1.5V AAA cells
Dimensions: 93 × 42 × 17 mm (3.7 × 1.7 × 0.7 inches)
IP Rating: IP4X

Reviews