Model EL-USB-TC

Single Channel Thermocouple Data Logger Supports TC types K, J, and T

$103.49

Select Data Security: 

  • Includes an EL-USB-TC data logger, a 1.5-meter K-type thermocouple probe, a battery (pre-installed), and downloadable software (CALIBRATION CERTIFICATE sold separately under ACCESSORIES tab and must be ordered at time of purchase)
  • -200 to +1300°C Measurement Range (K-type)
  • -130 to +900°C Measurement Range (J-type)
  • -200 to +350°C Measurement Range (T-type)
  • USB Interface for Set-up and Data Download
  • 2 User-Programmable Alarm Thresholds
  • Bright Red and Green LED Indication
  • Replaceable Internal Lithium Battery
  • Supplied with basic K-type thermocouple rated from 0 to 400°C (32 to 752°F)
  • Quantity Discount
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
EL-USB-TC Data Logger
This data logger has 0.5 degree of resolution.This data logger has a single channel.This data logger measures thermocouple temperatures type J, K, and T.This data logger can record one sample every second.This data logger has a USB interface.
This data logger records data to internal memory.21 CFR Part 11 Option Available.Get same day shipping when you order this data logger before 3PM ETThis data acquisition system has a 30-day Money back guaranteeUse coupon code EL10USB for 10% off your Lascar data logger purchase.

Description

The EL-USB-TC data logger measures and stores up to 32,510 temperature readings from either a J, K or T type thermocouple. A thermocouple is attached via the thermocouple socket at the base of the unit. The user can easily set up the thermocouple type, logging rate, start-time, logging mode, and download the stored data by plugging the data logger into a PC’s USB port and running the purpose-designed software. Data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life lithium battery, which will last for approximately 6 months.

Accessories

BAT 3V6

3.6V Battery

$5.99
Lascar Data Logger Battery

Description

Replacement 3.6V, 1200mAh lithium battery. Please Note: Continental U.S. shipping ONLY.

EL-P-TC-K

Thermocouple Probe

$23.99
K-type Thermocouple Probe

Description

K-type thermocouple probe. 1.5 meters (4.9 feet). View Dimensions.

DI-TCT

Thermocouple Connector

$6
Out of Stock
Miniature Thermocouple Connectors

Description

Type T miniature male thermocouple connector.

DI-TCK

Thermocouple Connector

$6
Out of Stock
Miniature Thermocouple Connectors

Description

Type K miniature male thermocouple connector.

DI-TCJ

Thermocouple Connector

$6
Out of Stock
Miniature Thermocouple Connectors

Description

Type J miniature male thermocouple connector.

CAL EL-USB-TEMP-1

Calibration Certificate (1st Cal Value)

$40.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase this first point option first for each device, and then additional points per device as required. Standard points are $40. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

CAL EL-USB-TEMP-2

Calibration Certificate (2nd Cal Value)

$25.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase the first point option first (CAL EL-USB-TEMP-1) for each device, and then additional points per device as required. Standard points are $25. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

Software

EasyLog Software

Configuration Software

FREE Configuration and download software for Lascar Data Loggers.

Lascar EasyLog Software

Specifications

Number of Channels: One
Measurement range (K-type): -200 to +1300°C (-328 to +2372°F)
Measurement range (J-type): -130 to +900°C (-202 to +1652°F)
Measurement range (T-type): -200 to +350°C (-328 to +350°F)
Resolution: 0.5°
Accuracy (logger error): ±1°C (±2°C)
Logging Rate: 1 sample every second
1 sample every 10 seconds
1 sample every minute
1 sample every 5 minutes
1 sample every 30 minutes
1 sample every hour
1 sample every 6 hours
1 sample every 12 hours
Memory Capacity: 32,000 samples
Operating Temperature Range: -10 to +40°C (+14 to +104°F)
Battery Life 6 months
(@ 25°C and 1m logging rate)

Using thermocouple sensors, the EL-USB-TC can log temperatures as detailed above, but the data logger should not be subjected to temperatures outside the Operating temperature range.

Videos

Introducing the EL-USB-TC Data Logger
Introducing the EL-USB-TC

Introducing the EL-USB-TC Low-cost USB Thermocouple data logger.
EasyLog Software
EasyLog Setup

Learn how to set up Lascar Data Loggers with EasyLog Software.
Reviewing EL-USB Recorded Data
EL-USB Data

Learn how to review recorded data on your EL-USB Data Logger.
EL-DataPad Setup
EL-DataPad Setup

Learn how to set up and configure your EL-USB data logger with the Optional EL-DataPad.
EL-USB Assembly
Assembly

View the animated gif showing typical EL-USB Data Logger assembly.

Similar Products

Reviews