Site Search:

Model DI-710-EHB

Bundle the DI-710-EH and save $373

$920.00
Discontinued. Please consider DI-2108P or DI-4108 for replacement

The DI-710-EHB contains the following products:

The DI-710-EH has the following features:

  • 16 single-ended, 8 differential analog inputs
  • Measurement range of ±1.25V to ±10V
  • 14-bit analog to digital conversion
  • Includes WinDaq Software
  • Up to 4800 Hz Sample Throughput Rate
  • Unlock code required for sample rates over 1,108 Hz only when using WinDaq software
  • Use HMP60 Relative Humidity (RH) and Temperature probe for environmental measurements.
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
DI-710 Ethernet Data Acquisition System
This DAQ system has 14-bit ADC resolutionThis data acquisition system features 8 differential or 16 single-ended analog input channelsThis data acquisition system features 8 digital I/O channelsThis device measures 1.25 Volts to 10 Volts.This data acquisition system can sample and record data at up to 4,800 samples per second throughput
This data acquisition has an Ethernet interfaceThis data acquisition system has a 30-day Money back guaranteeThis data logger is manufactured in the United States of America

Description

DI-710 General-purpose Ethernet Data Acquisition System with Windaq software. Features 8 differential or 16 single-ended analog input channels, 4,000 Samples per second throughput, 14-bit measurement resolution, and full scale ranges of ±1.25, ±2.5, ±5, ±10 V full scale.

The DI-710 Series of products is a family of instruments for general purpose and stand-alone data logger data acquisition applications. Options include interface type, input voltage range, and PC-connected or standalone data logger operation. Interface options are USB or Ethernet. Gain ranges have selectable factors per channel of 1, 2, 4, and 8, or 1, 10, 100, and 1000. Instruments with the stand-alone data logger option feature a built-in multimedia socket that accepts standard Secure Digital (SD) memories to which acquired data may be stored without a connected PC. SD memories are the same commonly available mass storage devices used with digital cameras and MP3 players. Memories ranging in size from 16 MB to 2 GB are supported. Instruments without this option must remain tethered to a PC’s USB or Ethernet port during data acquisition and use the PC’s own program and memory to store acquired data.

All DI-710 Series products feature 14-bit measurement resolution, sixteen analog input channels that may be configured for single ended or differential operation per channel, and an 8-bit digital bi-directional port. PC-connected instruments stream data to the PC from as low as 0.048 Hz up to as high as 4,800 Hz throughput rate. Stand-alone data loggers store to their SD memory from as low as 0.0017 Hz up to as high as 14,400 samples per second. All DI-710 instruments are supplied with two removable, 16-position screw terminal access connectors.

Accessories

WinDaq/Unlock 710

DI-710 High Speed Unlock Code

$595.00
WinDaq Unlock Code

Description

Unlocks WinDaq to allow recording speeds up to 4.8 kHz throughput. Unlock Code ONLY. No CD will be shipped. Please Note: If you are ordering this software for a device you already own, you MUST provide the serial number of your device under "Order Notes" during checkout to receive the unlock code. Please allow one (1) business day for processing.

R250

4-20mA Current Loop Shunt Resistor

$ 2.99
R250 Shunt Resistor

Description

250 Ω ±0.1% Precision, Metal Film, 1/2W, Axial Resistor
Exceptionally low noise; typically 0.10 μV/V
Low voltage coefficient to ±5 ppm/V
Flame retardant coating. RoHS compliant. Learn More

100995-MCVW

Screw Terminal Block (Bottom)

$10.00
16-port screw terminal block

Description

Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

100995-MCVR

Screw Terminal Block (Top)

$10.00
16-port screw terminal block

Description

Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

100952

Power Connector

$2.00
Ferrite Choke

Description

Power Connector for DI-1000TC, DI-710, and DI-718B products.

101017

Power Supply

$30.00
Spare power supply for DI-710, DI-718B, and DI-1000TC DAQs

Description

Spare power supply for DI-710, DI-718B, and DI-1000TC products.

101017-RPS

Australian Power Adapter

$4.00
Australian Power Adapter

Description

Spare Australian Adapter for AC power supply 101017-2 and 101085.

101017-RPK

UK Power Adapter

$4.00
UK Power Adapter

Description

Spare UK Adapter for AC power supply 101017-2 and 101085.

101017-RPE

EU Power Adapter

$4.00
European Power Adapter

Description

Spare European Adapter for AC power supply 101017-2 and 101085.

101017-RPA

US Power Adapter

$4.00
US Power Adapter

Description

Spare US Adapter for AC power supply 101017-2 and 101085.

HMP60

Temp/RH Probe

$325.00
Temperature and Humidity probe

Description

Temperature and humidity probe measures -40 to +60 °C and 0 to 100% RH. Learn more.

100947-1

Mounting Brackets

$49.00
Right-angle Mounting Brackets

Description

Pair of angle mounting brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments

NIST-71X-CAL

Calibration Certificate

$95.00
NIST Calibration Certificate

Description

Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for all DI-710, DI-718B, and DI-718Bx data acquisition and data logger products. Includes both before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.

Software

WinDaq

Data Acquisition Recording and Playback Software

Included FREE with your DI-710 purchase. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. 1108Hz maximum sample rate. For higher rates purchase the unlock code under the Accessories tab.

WinDaq Data Acquisition Software

ActiveX Controls

Programming

FREE ActiveX programming solutions for Dataq Instruments products. Free sample programs available. Compatible with LabView.

DATAQ ActiveX Controls

WinDaq/XL

WinDaq-to-Excel Real Time Link

Real-time data logging directly to Microsoft Excel (supports MS Office 2003 or higher). No programming required. Free Trial Version. Purchase full version on WinDaq/XL product page.

WinDaq Data Acquisition Software

Advanced CODAS

$595

Advanced analysis software add-on to WinDaq Waveform Browser software. Allows calculated channels, derivative, integration, moving average, automatic file management, automatic scaling, and more.

Advanced CODAS

Specifications

Analog Inputs
Number of Channels: 16SE/8DI (software selectable per channel)
Measurement Range Full Scale:
  Gain Range Accuracy* Resolution
PGL Models: 1 ±10V ±.05%FSR ±50μV ±1.22mV
  10 ±1V ±.05%FSR ±50μV ±122µV
  100 ±100mV ±.05%FSR ±50μV ±12.2µV
  1000 ±10mV ±.05%FSR ±50μV ±1.22µV
PGH Models: 1 ±10V ±.05%FSR ±50μV ±1.22mV
  2 ±5V ±.05%FSR ±50μV ±610µV
  4 ±2.5V ±.05%FSR ±50μV ±305µV
  8 ±1.25V ±.05%FSR ±50μV ±153µV
Input Impedance, single-ended: 1MΩ
Input impedance, differential: 1MΩ each input to common
Input bias current: 10µA for a 10V input, single channel
Input offset voltage: Auto-zero
Input offset current: 2nA (single channel)
Max. normal mode voltage: 30V DC or peak AC
Max. common mode voltage: 30V DC or peak AC
Common mode rejection: 80db, gain=1, 1KΩ unbalance
Channel-to-channel crosstalk rejection: -75db @ 100Ω unbalance
Gain temperature coefficient: 50 ppm/°C
Offset temperature coefficient: 0.25µV/°C
Digital filtering: Standard: Conditional over-sampling
Stand-alone: None
A/D Characteristics
Type: Successive approximation
Resolution: 14-bit
Monotonicity: ±2 LSB
Conversion Time: 69µs
Scanning Characteristics
Max. throughput sample rate: Standard: 4,800 Hz (requires Unlock Code)
Stand-alone: 14,400 Hz
When acquiring more than one channel at a gain of 100 max throughput is 7200 Hz
When acquiring more than one channel at a gain of 1000 max throughput is 900 Hz
Dependent on SD card used. Low speed SD cards can sample up to 2,000 Hz
High speed cards can sample up to 14,400 Hz. Some high speed cards cannot sample as high at 14,400 Hz but their capability can only be determined by trial and error (Model 101014-2G has been tested and approved).
Min. throughput sample rate: Standard: 0.0034 Hz
Stand-alone: 0.0017 Hz
Max. scan list size: 17 entries
Sample buffer size: 2kb
Controls (Stand-alone models)
Single push-button: Manual control Record and Standby
Calibration
Calibration cycle: One year
Digital I/O
Bits: 8 bidirectional bits
Configuration: Each bit is programmable as Input or Output
Output voltage levels: Min. "1" 3V @ 2.5mA sourcing
Max. "0" 0.4V @ 2.5mA sinking
Output current: Max. source, -2.5 mA
Max. sink, 2.5mA
Input voltage levels: Min. required "1" 2V
Max allowed "0" 0.8V
Ethernet Interface
Type: 10/100Base-T
Connector: RJ-45
Protocol: TCP/IP
Server Type: DHCP
Removable Memory (Stand-alone models)
Type: Standard SD (not SDHD or SDxC). Minimum speed of 13x. For sample rates above 2kHz SD speed should be 133x or higher.
Capacity: 16 MB to 2 GB
Real Time Clock (Stand-alone models)
Type: Date, hour, minute, second
Resolution: 1 second
Accuracy: 20 ppm
Indicators
Stand-alone models: Three-color LED indicating Record, Standby, and Error conditions
Standard models: Power LED
Transfer Rate to PC
Real Time: up to 4,800 samples per second
From Memory Card: up to 2,400 samples per second (Ethernet only)
General
Panel indicators: Mode LED
Panel-accessible Power: 5 VDC @ 10 mA max
Panel Controls: Control push button (Stand-alone models)
Panel Slots: Accepts SD-type flash memory
Input connectors: Two, removable sixteen position terminal blocks
Operating Environment: 0°C to 70°C
Enclosure: Aluminum base with steel wrap-around. Aluminum end-panels with plastic bezels.
Dimensions: 5.4375D × 4.125W × 1.5H inches (13.81D × 10.48W × 3.81H cm.)
Weight: 14 oz.
Power Requirements: USB (stand-alone): 9 to 36 VDC, 2 watts max
USB (non stand-alone): 5V @ < 2 watts max (supplied by USB port)
Ethernet: 9 to 36 VDC, 2.5 watts max

Videos

Introducing the DI-710 Voltage Data Acquisition and Data Logger System
Introducing the DI-710

The DI-710 features 16 analog inputs and a variety of options to choose from.
Connecting to your DI-71x-E over the Internet
DI-71X Internet Installation

Learn how to connect to your DI-71X Ethernet over the Internet through your router.
Connecting to your DI-71x-E over a LAN
DI-71X LAN Installation

Learn how to connect your DI-71X Ethernet over a Local Area Network (LAN)
DI-71X Ethernet Connection directly to the PC
DI-71X-E Direct Connection

Learn how to connect and install a DI-71XE directly to your PC with a Static IP address.
Exporting Data to Excel
Export data to Excel

Learn how to export data from WinDaq Waveform Browser to Microsoft Excel.
Introduction to WinDaq Data Acquisition Software
WinDaq Data Acquisition Software

Introduction to WinDaq Data Acquisition Software.

Reviews