Model DI-785
Industrial Data Acquisition System Featuring 32 DI-5B Signal Conditioning Module Inputs
Stock
This item is Obsolete and no longer available. Consider the DI-4718B to replace.
- Includes a DI-785 instrument, a 7-foot Ethernet cable, AC power cable, a screwdriver for signal connections, an NIST-traceable calibration certificate, and software on CD. Note: DI-5B amplifiers are purchased separately.
- From sensor to results with one product
- Accepts DI-5B series plug-in signal conditioning modules — use the DI-788 with DI-8B modules
- 32 analog input channels, expandable to over 150
- Ethernet interface supports synchronous and distributed data acquisition up to 100 meters apart. For greater distances between units, use the DI-789 Repeater Switch.
- Desktop unit with optional rack mount configurations
- 14-bit resolution
- Up to 180 kHz Sample Throughput Rate
- Unlock code required for sample rates over 240 Hz only when using WinDaq software
- WinDaq software support.
Description
DATAQ Instruments announces model DI-785, a new 32-channel data acquisition system designed specifically to accept DI-5B style modular signal conditioners and based on our Third Generation Ethernet (3GE) communications. The DI-785 is packaged in an enclosure that measures 16.5W × 18.5D × 3.5H inches (42.9W × 47D × 8.9H centimeters) that is suitable for placement on a desktop, or can be mounted in a standard 19-inch rack using optional brackets. It’s also the first product from DATAQ Instruments to feature a built-in switching AC power supply, allowing it to be powered directly from AC line voltage. The DI-785 features 14-bit resolution, programmable gain per channel of 1, 2, 4, and 8, a maximum sample throughput rate up to 180,000 samples per second, and two built-in 16-channel DI-5B module backplanes allowing up to 32 signal-conditioning modules. Measurements include thermocouple, voltage, strain, frequency, process current, RTD, and potentiometric.
The Ethernet communications interface connects the DI-785 to any local area network (LAN). Direct Internet access is also possible. This patented (US 7,792,139 B2) communication option uses standard CAT5 cable to yield continuous data acquisition throughput rates up to 180kHz. Multiple DI-785 and/or DI-788 products may be daisy-chained together to form an ad-hoc extended network of autonomous, yet fully synchronous data acquisition stations. Add any DI-720 and/or DI-730 for a complete data acquisition system for almost any measurement. Each station can sample at a different rate (up to 150kHz throughput) and still maintain full synchronization. Station separation can be as far as 100 meters.
Accessories
Description
DI-5B amplifiers offer the convenience to mix and match modules based upon measurement function and range to meet any application requirement, from the most simple to the most complex.
Description
WinDaq Data Acquisition software unlock code includes a CD (shipping charges apply). Allows you to record at speeds up to 180kHz throughput.
Description
WinDaq Data Acquisition software unlock code on CD (shipping charges apply). Allows you to record at speeds up to 180kHz throughput and record different channels at different rates.
Description
Upgrade to the latest version of WinDaq/Pro+. For registered users of WinDaq/Pro+ ONLY. CD will be shipped - shipping charges apply.
Description
Upgrade to the latest version of WinDaq with the latest unlock code. For registered users of WinDaq/Pro+ ONLY. No CD will be shipped. Unlock code ONLY. Please allow at least one business day for processing.
Description
Upgrade to the latest version of WinDaq with the latest unlock code. For registered users of WinDaq/Pro ONLY. CD will be shipped - shipping charges apply.
Description
Upgrade to the latest version of WinDaq with the latest unlock code. For registered users of WinDaq/Pro ONLY. No CD will be shipped. Unlock code ONLY. Please allow at least one business day for processing.
Description
Ethernet repeater board. Enhanced Ethernet switch expands the distance between synchronous units over 100 meters apart. Learn more.
Description
Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable calibration certificate for all DI-785 and DI-788 data acquisition and data logger products (DI-78B doesn't require calibration). Provides "after" data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.
Description
Rack mounting kit for DI-785 and DI-788 Industrial Data Acquisition systems.
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DAQ hardware purchase. Record up to 240 samples per second throughput. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. Record higher sample rates with an Unlock Code (see Accessories).
ActiveX Controls
Programming
FREE ActiveX programming solutions for Dataq Instruments products. Free sample programs available. Compatible with LabView.
WinDaq/XL
WinDaq-to-Excel Real Time Link
Real-time data logging directly to Microsoft Excel (supports MS Office 2003 or higher). No programming required. Free Trial Version. Purchase full version on WinDaq/XL product page.
Advanced CODAS
$595
Advanced analysis software add-on to WinDaq Waveform Browser software. Allows calculated channels, derivative, integration, moving average, automatic file management, automatic scaling, and more.
Specifications
Analog Inputs | |
Number of Channels: | 32 configured for DI-5B modules |
Channel Configuration: | Defined by DI-5B Module |
Measurement Range: | Defined by DI-5B Module |
Accuracy: | ±0.25% of full scale range, ±100 µV |
Resolution: | 1 part in 16,384 (14-bit) |
Input Impedance: | Defined by DI-5B Module |
Input offset voltage: | Defined by DI-5B Module |
Channel-to-channel crosstalk rejection: | -75db @ 100 kHz sample throughput rate |
Offset temperature coefficient: | ±10 PPM/°C, plus DI-5B module |
Analog Frequency Response: | Defined by DI-5B Module |
Digital filtering: | Peak, Valley, Average |
CJC Error: | ±1.5°C plus signal conditioning module (10-min. warm-up; still air; 2-amp max current draw for backplane; average IOS mode) |
Gain: | 1, 2, 4, 8 (software selectable per channel) |
Isolation (via DI-5B Modules) | |
Input-to-Output: | 1000V |
Channel-to-Channel: | 500V |
A/D Characteristics | |
Type: | Successive approximation |
Resolution: | 14-bit |
Sample Rate Timing Accuracy: | 50 PPM |
Sample Rate Timing Resolution: | 62.5 ns |
Integral Linearity Error: | ±1LSB |
Minimum Conversion Time: | 4 microseconds |
Scanning Characteristics | |
Max. throughput sample rate: | Single Unit: 180,000 Hz Multiple Units (daisy-chained): 150,000 Hz per unit |
Min. throughput sample rate: | 0.01526 Hz |
Max. scan list size: | 34 entries |
Sample buffer size: | 7500 samples |
Calibration | |
Calibration cycle: | One year |
Digital I/O | |
Bits: | 8 inputs and 8 outputs |
Input voltage levels: | Min. required “1” 2V; Max allowed “0” 0.8V |
Connections: | Two 37-pin D-sub male |
Ethernet Interface | |
Type: | 10/100Base-T |
Connector: | RJ-45 (Two: Primary and Expansion) |
Protocol: | TCP/IP |
Server Type: | DHCP or Fixed IP |
Cross-unit synchronization: | Via secondary Ethernet port (RJ-45) |
Rear Panel I/O Connections | |
Power Cable: | Standard receptacle |
Digital I/O and Monitor Out: | 37 pin D sub (2) |
Signal I/O: | Removable Phoenix-type screw terminals (8) |
General | |
Front Panel indicators: | Power LED and Active LED |
Certification: | CE (non-daisy chained, 3m CAT-5 cable) |
Rear Panel Controls: | AC Power Switch |
Internal I/O Connections: | DI-5B module inputs (32) |
Operating Temperature: | 0°C to 50°C |
Storage Temperature: | -55°C to 125°C |
Dimensions: | 16.5W × 18.5D × 3.5H in. 41.9W × 47.0D × 8.9H cm. |
Weight: | 11 lbs. (5Kg) |
Weight with 32 DI-5B modules: | 15.44 lbs. (7Kg) |
Power Characteristics | |
Type: | AC Line |
Voltage Range: | 88 to 264 VAC rms |
Current Range: | 1.3A @ 115VAC; 0.8A @ 230 VAC |
Frequency Range: | 47 to 63 Hz |
Articles
WinDaq Monitors and Documents Control Rod Drive Welds
Data Acquisition Tips and Techniques
Synchronized and Distributed Data Acquisition in Hot Strip Steel Mills
Bridge Structural Monitoring System
Learn the Importance of Isolation In Four Easy Lessons
Enhancing Data Acquisition with Intelligent Over Sampling (IOS)
How To Choose Strain Gage-based Transducers for PC-based Data Acquisition Applications
Intelligent Oversampling Methods Extend Measurement Flexibility
Frequency and True RMS Data Acquisition
The Art and Science of Reliability
Strain Gage-Based Transducer and Amplifier Selection and Calibration
EN-B Ethernet Communications and Installation Issues (Windows 7 and 8)
EN-B Ethernet Communications and Installation Issues (prior to Windows 7)
Videos
Distributed and Synchronized
Distributed Synchronous Ethernet data acquisition with DI-720/730 Systems.