DI-2108XL
High Speed Excel Data Acquisition System and Stand-alone Data Logger, 32GB USB Flash Drive, 8 Analog Inputs, ±10 V, 160kHz, Anti-aliasing Filter, 7 D I/O
Stock
- Includes a DI-2108 instrument, a 6-foot USB cable, a screwdriver for signal connections, an NIST-traceable Calibration Certificate, and a 32GB USB flash drive with downloadable ExcelLink and WinDaq software
- Included WinDaq ExcelLink ($99 value) is able to capture and stream data to Excel spreadsheet in real time, up to 160K s/s
- Capable of recording to both Excel and WinDaq files simultaneously
- Supports both 32- and 64-bit version of Excel.
- Uses predefined Excel workbook for real time analysis and charting
- Window trigger to capture data inside or outside a range
- Slope trigger to capture data when reading crossing a point
- Event trigger to capture single row when an event happens
- Derivative trigger to trigger on rate of change, such as a glitch
- Paced Trigger to capture a single row at predefined pace
- Delayed Trigger to capture data after a predefined delay from the trigger point
- Digital Channel Trigger to capture data based on digital input conditions
- Manual trigger to capture data based on manual operation
- Use Excel Template for predefined analysis and report generation, all in real time
- Included 8 Channels+Stand-alone capability ($99 value) records data in WinDaq or Excel compatible CSV file to USB thumb drive
- Eight 10V armored analog differential inputs
- Adaptable anti-alias filter per channel - Corner frequency set as a function of sampling rate
- Up to 16-bit analog-to-digital resolution (Calculate Resolution)
- Seven digital ports programmable per port as input or switch
- Published protocol for software development in all operating systems
- Find out how long your data logger can record to removable flash memory with our Record Time Calculator
Description
DI-2108XL High Speed USB Data Acquisition and Data Logger System with Windaq software and 32GB USB flash drive. Features 8 differential analog 10V input channels, and stand-alone data recording to removable USB thumb drive.
DI-2108XL delivers premium analog performance at a surprisingly affordable price. The differential input configuration provides noise rejection, easily adapts to singleended signal sources, and is protected up to ±50 V dc or peak ac so that inevitable measurement mishaps will not harm the instrument. The front-end feeds a flexible resolution analog-to-digital converter that ranges from 12 to 16 bits as a function of sampling rate. Lower sampling rates deliver higher resolution readings. Rounding off the analog subsystem are anti-alias filters per channel with automatic selection of corner frequency at approximately one tenth of the sampling frequency.
DI-2108XL provides 7 digital ports, each configurable as an input or a switch. Input protection is provided to 25 V. When activated as inputs two ports allow dual functionality as discrete inputs, or programmed as a counter or rate input. The rate input features a 50 kHz maximum measurement allocated over twelve programmable measurement ranges (10 Hz to 50 kHz full scale.) The counter input provides 16-bit resolution and a terminal count value of 65,535. The discrete, counter, and rate inputs are members of the same internal scan list used by the analog input channels. This means that all enabled elements are acquired synchronously, which allows meaningful comparisons between analog and digital channels. For example, the rate input measuring engine speed allows rpm data to be acquired in lock-step with analog data. Configured as a switch a digital port can be used to control external loads up to 25 V @ 100 mA, and the switch can be controlled asynchronously without interfering with the scanning process.
A USB drive is used to record data in stand-alone mode. Two file formats are supported, Excel compatible CSV file forma and WinDaq file. With Excel compatible CSV format, DI-2108XL can record 200 rows of data per second. With WinDaq file, sample rate of 160K is possible with industrial grade SCL microSD card.
Real Time Trigger Excel Link
The DI-2108XL comes with WinDaq ExcelLink. It provides real-time conection to Excel spreadsheet (32- or 64-bit) and can stream data to Excel spreadsheet at high speed. Four trigger methods are provided - two-point window trigger, one-point slope trigger with pre- and post-trigger data, manual single row and block trigger, and programmable event driven single-row trigger.
Even though Excel can store over 1,000,000 rows of data, it is still a small buffer for high speed data aquisition unless trigger modes are utilized so that only data of interests is captured. ExcelLink supports advanced math to construct trigger methods. Window trigger can capture signals inside or outside a range. Slope trigger with pre- and post- trigger can capture signals before and after a predefined trigger point. Event trigger can capture a single row of data at the moment trigger conditions are met. Derivative trigger to trigger on rate of change, such as a glitch. Manual trigger can capture signals at operator's key instruction.
With data directly streaming to Excel, powerful real time analysis and many charting options are available, such as grouping multiple channels in a single chart.
Accessories
Description
250 Ω ±0.1% Precision, Metal Film, 1/2W, Axial Resistor
Exceptionally low noise; typically 0.10 μV/V
Low voltage coefficient to ±5 ppm/V
Flame retardant coating. RoHS
compliant. Learn More
Description
Not all rechargable batteries are created equal. In addtion to charging your phone, we test and make sure our battery can power DI-2160, DI-2108, DI-2108P, DI-4108 or DI-4208 for standalone recording that lasts for days. 20000mAH capacity
Description
32GB 3.0 USB flash drive for stand-alone recording up to 10,000 Samples per second throughput.
Description
1 GB Industrial Industry-grade high speed SLC microSD flash memory card. Recommended for recording rates higher than 80K S/s throughput rate and harsh environment. microSD Card Reader (Part#2000352) is needed
Description
32 GB Industry-grade high capacity microSD flash memory card. Recommended for recording rates between 10,000 S/s and 40,000 S/s throughput rate and harsh environment. microSD Card Reader (Part#2000352) is needed
Description
Micro SD Card Reader with USB A interface. Hi-Speed USB 2.0 compatible transfer rates. No additional card adapters required
Description
AC Adapter for Sensor (such as 4-20mA) Excitation. Input: AC 100V-240V 50/60Hz; Output: 12V, 2A. Power Cable Length: 36.6 inch (0.9m).
Description
2000361-H High precision pressure sensor measures PSI ranges of -14.5 up to 10000 PSI dependant on model. Made with 316 stainless steel and high temperature auto-graded plastic. 0.5% accuracy. 0.5V – 4.5V linear voltage output.
Description
2000361-HX 4-20mA Output High precision pressure sensor measures PSI ranges of -14.5 to 10000 PSI dependant on model. 8-30V supply voltagle, such as a car battery. Made with 316 stainless steel and high temperature auto-graded plastic. 0.5% accuracy. 4-20mA linear current output.
Description
Allows you to power data logger with a battery. Input voltage: DC8-35V, (12V/24V changes to 5V); Output parameter: DC5V 3A, 15W MAX
Description
Ferrite choke reduces interference for USB-based data acquisition products.
Description
Optional USB Cable for use with ChannelStretch™. Dual ferrite cores provide maximum protection against ground bounce that could lockup your PC's USB port during data acquisition. 20.4-inch (520 mm) overall cable length. Recommended whenever products are deployed in our ChannelStretch™ configuration.
Description
Powered 7 port USB hub to synchronize multiple USB devices. Please note: Not all DATAQ Instruments devices support synchronization - check your product datasheet or product page for detailed information. Note: Provided with a US ac adaptor only, and is not suitable for use in countries that require an ac mains connector other than the US type.
Description
16-ft USB Extension Cable. USB 2.0 Type A. Daisy chain up to 5 cables for extended length.
Description
Optional AC power supply (USB to AC) for stand-alone applications and charging EL-WiFi Series products. Includes US adapter.
Description
YF-S201 Flow Sensor Measures 1-30L/min. Light weight, small size, durable, and easy to install. Inlaid with stainless steel impeller shaft. Lowest working voltage: DC4.5 5V-24V; Max current: 15 mA (DC 5V); Max operation temp: 120°C. Learn more.
Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for model DI-2108 high speed data acquisition product. Includes before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.
Description
Spare European Adapter for AC power supply 101017-2 and 101085.
Description
Spare UK Adapter for AC power supply 101017-2 and 101085.
Description
Spare Australian Adapter for AC power supply 101017-2 and 101085.
Description
AC/DC Current Clamp includes 9V battery and user manual. Download the DataSheet (pdf) to learn more or go to the product page.
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DI-2108 purchase. Record as many as 4 channels at 160,000 samples per second throughput. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. Record all 8 channels with an Unlock Code (see Accessories).
Frequently Asked Questions
Can I record 4-20mA sensor signals and if so, how do I do that?
4-20-mA process current signals can be measured with the DI-2108. See How to make 4-20mA current Loop Measurements for more information.
Does the device have internal memory (i.e. can I record in stand-alone mode)?
Though the DI-2108 does not have internal memory you can record data to a removable USB thumb drive (included with purchase). Configure the device with your PC then deploy in the field. An unlock code is required to store more than one channel to the USB thumb drive.
What kind of thumb drive can I use?
Almost any off-the shelf thumb drive can be used but could cause gaps in data. The thumb drives provided on our web site are tested and rated for speed. For higher speeds we recommend using the SLC micro SD card with a USB A microSD card reader available in Accessories.
Can I connect and measure data from a single-ended sensor?
Yes. Single-ended sensors can be connected and measured. The best practice is to connect the ground wire to the negative input of the channel.
Can I measure Thermocouple temperatures?
Thermcouple temperature measurements would not be accurate using the DI-2108 and should not be attempted. Thermocouple measurements are non-linear and require special programming to provide accurate readings.
Is software included with the device?
WinDaq Data Acquisition and Playback Software is included free.
Where do I download the software?
Download ExcelLink at https://dataq.com/support/downloads/WinDaq-Acquisition-Add-ons-Setup.exe.
Download WinDaq at https://www.dataq.com/support/downloads/DATAQ-Software-Suite-Web-Setup.exe.
Does the DI-2108 include a calibration certificate?
All new DI-2108 instruments ship with an NIST-traceable calibration certificate.
Can I get the DI-2108 re-calibrated?
Recalibration service is available and can be ordered online.
How often should I get the DI-2108 re-calibrated?
The DI-2108 should be re-calibrated annually.
Is my sensor compatible with this device?
Maybe. Sensors with an output within the range of ±10 Volts can be used with the DI-2108. See how fine a measurement you can make with your sensor using the ADC Resolution Calculator. If you have any questions about compatibility just send your sensor information to our sales team at sales@dataq.com.
Is the DI-2108 Isolated?
The DI-2108 is not an isolated instrument. The armored analog inputs can withstand up to ±50 V without damage.
Does the DI-2108 include digital or analog output channels?
The DI-2108 has seven bi-directional digital ports that can be programmed as an input or switch..
My sensor requires a power source, can the DI-2108 provide that power?
Yes. The DI-2108 can provide +5V power by connecting the appropriate wire to the +5V pin.
Specifications
Analog Inputs | |
Number of Channels: | 8 |
Configuration: | Differential |
Full Scale Range: | ±10 V full scale fixed |
Input impedance: | 110 kΩ |
DC accuracy: | ±5 mV at 16-bit resolution 25°C, excluding common mode error |
Absolute maximum input without damage: | ±50 V dc or peak ac (normal mode + common mode) |
Common mode range: | ±10 V dc or peak ac |
Common mode rejection ratio: | 80 dB (dc - 60 Hz) |
Channel-to-channel crosstalk rejection: | -80 dB |
Digital Inputs | |
Number of ports: | 7 |
Type: | MOSFET switch |
Configuration: | Programmable as digital input or switch |
Pull-up value: | 4.7 kΩ |
Input high voltage threshold: | 2.4V |
Input low voltage threshold: | 0.8V |
Absolute maximum applied voltage (V): | 0 ≤ V ≤ 25 V |
Reserved Digital Inputs | |
Port 1: | WinDaq remote events |
Port 2: | WinDaq remote start/stop |
Port 3: | Rate input |
Port 4: | Count input |
Digital Ports Programmed as Switch | |
Maximum drain voltage: | 25 V |
Maximum sink current: | 100 mA |
Count/Rate Inputs | |
Digital port assignment: | Count: Port 2 configured as input Rate: Port 3 configured as input |
Internal pull-up value: | 4.7 kΩ |
Input high voltage threshold: | 2.4V |
Input low voltage threshold: | 0.8V |
Terminal count: | 65,535 |
Maximum rate frequency: | 50 KHz with one enabled channel, 20 KHz with 2-4 enabled analog channels, otherwise 10 KHz. |
Minimum rate frequency: | 0.5 Hz |
Maximum count frequency: | 50 kHz |
Power | |
Power Consumption: | <1.0 Watt, via USB interface |
ADC Characteristics | |
Resolution: | 12 to 16-bit |
Above zero ADC counts: | 2,047 to 32,767 |
Below zero ADC counts: | 2,048 to 32,768 |
Maximum sample throughput rate: | 160,000 S/s |
Minimum sample throughput: | Hardware only: 20 S/s WinDaq software: 2.2 samples per hour |
Sample rate timing accuracy: | 50 ppm |
Removable Memory | |
Type: | MLC, pSLC, or SLC flash memory (with USB SD card reader); USB thumb drive |
File Format | CSV (Excel compatible) or WinDaq (Higher capacity and max speed) |
Required Format: | FAT32 |
Indicators and Connections | |
Interface: | USB 2.0 (mini-B style connector) |
Status LED: | Multi-color LED |
Input Connections: | Two 16-position terminal strips |
Environmental | |
Operating Temperature: | 0 to 50 °C |
Operating Humidity: | 0 to 90% RH non-condensing |
Storage Temperature: | -20 to 60 °C |
Storage Humidity: | 0 to 90% non-condensing |
Marking | CE, UKCA |
Physical Characteristics | |
Enclosure: | Polycarbonate ABS, 0.080 inch thickness |
Mounting: | Desktop; bulkhead |
Dimensions: | 3.28D × 6.68W × 1.13H in. (83.31D × 169.67W × 28.7H mm.) |
3D Model | Click here |
Weight: | 5.7 oz. (162 grams) |
Software Support | |
WinDaq software: | OS support |
Programming: | Instrument protocol, ActiveX Control |
Articles
How to Acquire Flow Rate and Flow Volume using a DATAQ Data Logger
Making Pressure Measurements with a Dataq Data Logger and Pressure Sensor
Intelligent Oversampling Methods Extend Measurement Flexibility
4-20mA Current Loop Data Acquisition
4-20 mA Measurement Resolution
Videos
Pressure Measurements
Learn how to make pressure Measurements with a pressure sensor and Dataq products.