Model EL-CC-2
Cold Chain Goods Temperature and Humidity Data Loggers
Select Goods Type:
For CHILLED foods - has a low alarm of 2°C (35.6°F) and a high alarm of 8°C (46.4°F).
Stock
- Includes an EL-CC-2 data logger and quick start guide. Sold as 10-pack.
- Single-use Temperature and RH data loggers for Food and Agriculture Market
- Sold in 10-packs for one of three food- and agricultural-related environments:
- Chilled Goods (2 to 8 °C)
- Frozen Foods (-20 to -16 °C)
- Ripening Goods (12 to 14 °C)
- All also measure RH (0 to 100%)
- Encapsulated packaging seals out dust and water up to 1 meter of immersion (IP67)
- Samples and records temperature and RH with a time and date stamp once every 10 minutes
- Maximum record time is over 220 days
- Built-in alarm LED set to trigger at pre-configured temperature limits
- Data export options include PDF, Excel, JPEG image
- All software is included
- Quantity Discount
Description
Simplicity, accuracy, and confidence define the EL-CC Data Logger approach to ensure that food stuffs of any type were not exposed to dangerous temperature extremes during transit and handling. Packaged in their own hermetically sealed bag, EL-CC data loggers are offered as three individual models each configured to alarm at a specific temperature range: one model each for frozen, chilled, and ripening food stuffs.
The data loggers can be initiated on-the-spot and placed into service without the need for configuration software. A preprogrammed 30-minute delay prevents alarms from triggering until the logger is fully saturated in the ambient temperature it's monitoring. The logger samples at a fixed rate of one sample every 10 minutes, and contains enough memory to provide over 220 days of total record time. At any time during the recording process the logger's control button can be pressed to activate built-in LEDs. That action saves a marker in the recorded data stream to indicate the event. At the same time the LEDs illuminate to indicate device status and alarm states.
If pre-programmed temperature extremes were breached, the LEDs provides an instant visual indication of the problem without the need to download and review recorded data. After deployment the logger may be connected to the USB port of a PC to upload all recorded temperature, humidity, and event data, each correlated with a specific date and time of acquisition. Data can be sent to a PDF, Excel, or JPEG image file. Software is downloadable and provided at no extra charge. The life of the EL-CC-2's built-in battery exceeds the instrument's >220-day total record time.
Accessories
Description
Pack of 5 waterproof bags when reusing any version of the EL-CC-1 data logger.
Specifications
Number of Channels: | One |
Temperature Measurement Range: | -30 to +60°C (-22 to +140°F) |
Temperature Internal Resolution: | 0.1°C (0.2°F) |
Temperature Accuracy (overall error): | ±0.3°C (±0.7°F) |
Humidity Measurement Range: | 0 to 100% RH |
Humidity Internal Resolution: | 0.1% RH |
Humidity Accuracy (overall error): | ±2% RH typical |
Logging Rate: | 1 sample every 10 minutes |
Memory Capacity: | 32,637 samples |
Environmental protection: | IP67 (protected against moisture to the IP67 standard when housed in its original, unopened packaging, or an optional EL-CC-BAG or equivalent) |
Battery Life: | 1 year |
Maximum Possible Record Time: | 220 years |