Model EL-GFX-2
Graphing Temperature and Humidity Data Logger measures Temperatures from -30°C to +80°C (-22°F to +176°F and 0 to 100%RH)
Stock
- Includes an EL-GFX-2 data logger, a 31-inch USB cable, a mounting clip, two batteries (pre-installed), and downloadable software (CALIBRATION CERTIFICATE sold separately under ACCESSORIES tab and must be ordered at time of purchase)
- -30 to +80 °C (-22 to 176 °F) and 0 to 100%RH measurement range
- Stand-alone operation
- Powered by replaceable batteries
- Built-in temperature sensor
- Built-in date and time clock
- Deep on-board memory of 251,928 readings
- Built-in graphics display for temperature trending, high/low capture, and more
- IP67 construction resists dust ingress and water submersion up to 1 meter
- Programmable high/low alarm thresholds
- Both audible and visual alarm states
- Quantity Discount
Description
The EL-GFX-2 data logger offers a cost-effective approach to temperature and humidity data logging. Its integrated USB interface allows the instrument to be configured by any Windows-based PC. Typical programmable parameters include a unique data logger name, °F or °C temperature scale, sampling interval (10 seconds to 1 hour), high and low alarm limits, security settings, triggered recording parameters, and more. The GFX-2 is powered by two replaceable (non-rechargeable) ½ AA lithium batteries, for long-life recordings typically up to one year.
Model EL-GFX-2 provides a security option that can prohibit tampering of the logger in any manner that would affect recorded data after deployment.
The GFX also supports a programmable alarm delay feature, from immediate to after 250 readings. This is useful where temperature or RH are known to fluctuate momentarily into an alarm threshold, but does not necessarily indicate an alarm condition. For example, the logger is placed inside a freezer or refrigerator. If the door opens the temperature will momentarily rise, but the logger can be configured to ignore that increase for a programmed number of samples before triggering an alarm.
During deployment, status LEDS provide continuous visual feedback of sampling events, battery status, and alarm states. In addition, three front panel function buttons allow you to view the memory consumed (0-100 %), the number of readings contained in the logger’s memory, and the current battery capacity (0-100 %.) The last recorded temperature/RH reading can also be viewed, along with historical data in the form of minimum and maximum values logged during the current recording cycle, as well as an historical trend plot. Using front panel buttons you can also start and stop the logger and view pre-programmed alarm thresholds.
The GFX-2 is programmed using software that is provided with the instrument. The software programs all operating parameters and options. When a logging session is complete, the GFX logger is plugged into any computer onto which the software is installed using the supplied cable. Options in the software allow the GFX logger to upload time, date and recorded data to the PC where they can be graphed in a cursor-based chart that displays temperature/RH as a function of recorded time and date. A single mouse click can export the data to Microsoft Excel for detailed analysis and report generation.
The EL-GFX-2 is provided with everything you need to begin taking temperature and humidity measurements: USB cable for connecting it to a PC, batteries, and software (downloadable, no CD provided.) Also provided is a convenient wall clip that can be either permanently attached to a surface, or temporarily attached to a ferrous surface via the integrated magnet.
Accessories
BAT 3V6
3.6V Battery
Description
Replacement 3.6V, 1200mAh lithium battery. Two (2) required for use with this data logger. Please Note: Continental U.S. shipping ONLY.
CAL EL-USB-TEMP/RH-1
Calibration Certificate (1st Cal Value)
Description
Before purchasing please read the blog post Lascar Data Logger Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase this first point option first for each device, and then additional points per device as required. Standard points are $90. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.
CAL EL-USB-TEMP/RH-2
Calibration Certificate (2nd Cal Value)
Description
Before purchasing please read the blog post Lascar Data Logger Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase the first point option first (CAL EL-USB-TEMP/RH-1) for each device, and then additional points per device as required. Standard points are $25. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.
Software
EasyLog Software
Configuration Software
FREE Configuration and download software for Lascar Data Loggers.
Specifications
Number of Channels: | One |
Temperature Measurement Range: | -30 to +80°C (-22 to +176°F) |
Temperature Resolution: | 0.1°C (0.2°F) |
Temperature Accuracy (overall error): | Typical: ±0.5°C (±1°F) Maximum: ±2.0°C (±4.0°F) |
Temperature Repeatability: | ±0.1°C (±0.2°F) |
RH Measurement Range: | 0 to 100% RH |
RH Resolution: | 0.1% RH |
RH Accuracy (overall error): | Typical: ±3.0% RH Maximum: ±5.0% RH This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 80%RH. |
RH Repeatability: | 0.5% RH |
RH Long term stability: | 0.5% RH/year |
Dew Point Accuracy (overall error): | ±1.1°C (±2.0°F) This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100%RH at 25°C. |
Logging Rate: | 1 sample every 10 seconds 1 sample every 15 seconds 1 sample every 20 seconds 1 sample every 30 seconds 1 sample every 1 minute 1 sample every 5 minutes 1 sample every 10 minutes 1 sample every 15 minutes 1 sample every 20 minutes 1 sample every 30 minutes 1 sample every 1 hour |
Memory Capacity: | 251,928 samples |
Operating Temperature Range: | -30 to +80°C (-22 to +176°F) (at temperatures below -5°C the LCD will exhibit slower response times - the LCD will be disabled at temperatures under -20°C and above 70°C) |
Battery Life | 1 year (at 25°C and 10 minute logging rate, with no alarm LEDs or sounder and minimal LCD use) |