Site Search:

Model DI-8B47J-12

Isolated J-type Thermocouple -100°C to +760°C (-148°F to +1400°F) 8B-style Amplifier

$ 152 each
Limited availability, 2-8 week lead time for higher quantity
  • Measures -100°C to +760°C (-148°F to +1400°F)
  • Interfaces to Thermocouple Type J
  • ±2.10°C Accuracy + CJC error
  • Linearizes Thermocouple Signal
  • High Level Voltage Outputs
  • 1500Vrms Transformer Isolation
  • ANSI/IEEE C37.90.1
  • Input Protected to 240VAC Continuous
  • 120dB CMR
  • 70dB NMR at 60Hz
  • Low Drift with Ambient Temperature
  • CJC range: -40°C to +85°C
  • CSA, FM, and CE Certifications Pending
  • Mix and Match Modules
  • View Dimensions and pinout
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
DI-8B DAQ Amplifiers
This amplifier module measures -100°C to +760°C (-148°F to +1400°F).This amplifier module interfaces with a J-type Thermocouple.This amplifier module has 3Hz bandwidth.This data acquisition system has a 30-day Money back guaranteeThis amplifier is manufactured in the United States of America

Description

DI-8B modules are an optimal solution for monitoring real-world process signals and providing high level signals to a data acquisition system. Each DI-8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output.

Linearization is accomplished using a four breakpoint piecewise linear approximation.

The DI-8B47 can interface to industry standard thermocouple type J, K, and T and has an output signal of 0V to +5V. Each module is cold-junction compensated to correct for parasitic thermocouples formed by the thermocouple wire and screw terminals on the mounting backpanel. Upscale open thermocouple detect is provided by an internal pull-up resistor.

Signal filtering is accomplished with a three-pole filter optimized for time and frequency response which provides 70dB of normal-mode-rejection at 60Hz. One pole of this filter is on the field side of the isolation barrier for anti-aliasing, and the other two are on the system side.

A special input circuit on the DI-8B47 module provides protection against accidental connection of power-line voltages up to 240VAC.

The modules are designed for installation in Class I, Division 2 hazardous locations and have a high level of immunity to environmental noise.

Accessories

8BP02

2-Position Backplane

$ 95
8BP02

Description

2-position analog I/O backplane, non-multiplexed. For use with DI-8B Modules. View the 8BP02 schematic or the 8BPxx schematic or download the pdf.

8BP04

4-Position Backplane

$ 153
8BP04

Description

4 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP04 schematic or the 8BPxx schematic or download the pdf.

8BP08

8-Position Backplane

$ 228
8BP08

Description

8 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP08 schematic or the 8BPxx schematic or download the pdf.

8BP16

16-Position Backplane

$ 355
8BP16

Description

16 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP16 schematic or the 8BPxx schematic or download the pdf.

DI-5B-PS

Power Supply

$65.00
Power Supply

Description

5V DC Power Supply for use with both DI-5B and DI-8B Backplanes.

Specifications

Input Range: -100°C to +760°C (-148°F to +1400°F)
Thermocouple Type: J
Accuracy: ±0.24% ±2.10°C
Includes conformity, hysteresis, and repeatability. Does not include CJC Accuracy.
Input Bias Current: -25nA
Input Resistance: Normal: 50MΩ
Power Off: 200kΩ
Overload: 200kΩ
Input Protection: Continuous: 240VAC (8B30-01: 120VAC)
Transient: ANSI/IEEE C37.90.1
CMV, Input to Output: Continuous: 1500Vrms
Transient: ANSI/IEEE C37.90.1
Transient, Input to Output: ANSI/IEEE C37.90.1
CMR (50Hz or 60Hz): 120dB
Stability: Offset: ±20ppm/ºC
Gain: ±75ppm/ºC
Noise: Output, 100kHz: 250µVrms
Bandwidth, -3dB: 3Hz
Response Time, 90% Span: 150ms
Output Range: 0 to +5V
Output Protection: Transient: Continuous Short to Ground
ANSI/IEEE C37.90.1
Cold Junction Compensation: Accuracy, 25ºC: ±1.25ºC
Accuracy, -40ºC to +85ºC: ±8.30ºC
Power Supply Voltage: +5VDC ±5%
Power Supply Current: 30mA
Power Supply Sensitivity: ±100ppm/%
Mechanical Dimensions: 1.11" × 1.65" × 0.40"
(28.1mm × 41.9mm × 10.2mm)
Operating Temperature: -40ºC to +85ºC
Storage Temperature: -40ºC to +85ºC
Relative Humidity: 0 to 95% Noncondensing

Compatible Products