Stock
- Includes a DI-1100 instrument, a 6-foot USB cable, a screwdriver for signal connections, and downloadable ExcelLink and WinDaq software (All new DI-1100 devices are calibrated but they do not include an NIST-traceable calibration certificate. Consider the DI-2108XL if NIST traceability is required)
- Included WinDaq ExcelLink ($99 value) is able to capture and stream data to Excel spreadsheet in real time
- Capable of recording to both Excel and WinDaq files simultaneously
- Supports both 32- and 64-bit version of Excel.
- Uses predefined Excel workbook for real time analysis and charting
- Window trigger to capture data inside or outside a range
- Slope trigger to capture data when reading crossing a point
- Event trigger to capture single row when an event happens
- Derivative trigger to trigger on rate of change, such as a glitch
- Paced Trigger to capture a single row at predefined pace
- Delayed Trigger to capture data after a predefined delay from the trigger point
- Manual trigger to capture data based on manual operation
- Use Excel Template for predefined analysis and report generation, all in real time
- Great launch pad for Python and Pandas with Excel
- Low-cost, Compact USB Data Acquisition for Excel
- Four ±10 V Differential Analog Inputs
- 5mV resolution
- High sample rates per channel (dependent on the number of channels enabled):
- 40 kHz per channel, 1 enabled channel
- 30 kHz per channel, 2 enabled channels
- 24 kHz per channel, 3 enabled channels
- 20 kHz per channel, 4 enabled channels
- 2 Dedicated Digital Inputs
- Analog inputs are protected to ±100 V
- Digital inputs are protected to ±30 VDC or peak AC
- Protocol provided for development
- CE approved
- 10% Education Discount
- Does this product have enough resolution for your application? Find out with our ADC Resolution Calculator
Description
DI-1100XL USB Data Acquisition starter kit with Windaq software. Features four differential analog input channels, 12-bit measurement resolution, and a full scale range of ±10V.
Suitable for measuring preamplified analog signals, the DI-1100XL with included ExcelLink and WinDaq software allows real time data acquisition to Excel, playback, and analysis performance equal to or better than other products that cost many times its low price. The DI-1100 offers four analog input and two discrete (digital) input channels. The analog inputs offer a fixed measurement range of ±10VFS, and are multiplexed to an integrated 12-bit ADC. Digital inputs are protected to ±30 V dc. Sample rates as slow as 20 Hz and as fast as 40 kHz with a single enabled channel are supported.
Real Time Trigger Excel Link
The DI-1100XL comes with WinDaq ExcelLink. It provides real-time conection to Excel spreadsheet (32- or 64-bit) and can stream data to Excel spreadsheet at high speed. Four trigger methods are provided - two-point window trigger, one-point slope trigger with pre- and post-trigger data, manual single row and block trigger, and programmable event driven single-row trigger.
Even though Excel can store over 1,000,000 rows of data, it is still a small buffer for high speed data aquisition unless trigger modes are utilized so that only data of interests is captured. ExcelLink supports advanced math to construct trigger methods. Window trigger can capture signals inside or outside a range. Slope trigger with pre- and post- trigger can capture signals before and after a predefined trigger point. Event trigger can capture a single row of data at the moment trigger conditions are met. Derivative trigger to trigger on rate of change, such as a glitch. Manual trigger can capture signals at operator's key instruction.
With data directly streaming to Excel, powerful real time analysis and many charting options are available, such as grouping multiple channels in a single chart.
Accessories
Description
250 Ω ±0.1% Precision, Metal Film, 1/2W, Axial Resistor
Exceptionally low noise; typically 0.10 μV/V
Low voltage coefficient to ±5 ppm/V
Flame retardant coating. RoHS
compliant. Learn More
Description
Ferrite choke reduces interference for USB-based data acquisition products.
Description
AC Adapter for Sensor Excitation.: AC input: 100V-240V. DC output: 5V 2A. Cable length: 2.95ft. DC plug connector size: 5.5x2.5mm. Includes screw terminal connector.
Description
Pressure sensor measures PSI ranges of 0-30 up to 0-500 PSI dependant on model. Requires seperate 5V power supply. Made with 316 stainless steel and high temperature auto-graded plastic. 2% Accuracy. 0.5V – 4.5V linear voltage output.
Description
AC Adapter for Sensor (such as 4-20mA) Excitation. Input: AC 100V-240V 50/60Hz; Output: 12V, 2A. Power Cable Length: 36.6 inch (0.9m).
Description
2000361-HX 4-20mA Output High precision pressure sensor measures PSI ranges of -14.5 to 10000 PSI dependant on model. 8-30V supply voltagle, such as a car battery. Made with 316 stainless steel and high temperature auto-graded plastic. 0.5% accuracy. 4-20mA linear current output.
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DI-1100 purchase. Record as many as 4 channels at 20,000 samples per second each. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key.
WinDaq Add-ons and Utilities
Library
Library of add-on packages for WinDaq Software, such as live XY plot, FFT, Spectrogram, Meter, Gauge, Alarm, etc.
Frequently Asked Questions
Can I record 4-20mA sensor signals and if so, how do I do that?
4-20-mA process current signals can be measured with the DI-1100. See How to make 4-20mA current Loop Measurements for more information.
Does the device have internal memory (i.e. can I record in stand-alone mode)?
The DI-1100 stores acquired data to a connected PC using either WinDaq Acquisition software or by writing your own program. The device does not have hardware to store data to internal memory or removable memory. The nearest device that can is the DI-2108.
Can I connect and measure data from a single-ended sensor?
Yes. Single-ended sensors can be connected and measured. The best practice is to connect the ground wire to the negative input of the channel.
Can I measure Thermocouple temperatures?
Thermcouple temperature measurements would not be accurate at all using the DI-1100 and should not be attempted. Thermocouple measurements are in the 50mV to 100mV range. With a 12-bit ADC converter and a full scale range of ±10V makes the DI-1100 very ineffective. Thermocouple measurements are also non-linear and require special programming to provide accurate readings.
Is software included with the device?
WinDaq Data Acquisition and Playback Software and ExcelLink are included.
Where do I download the software?
Download ExcelLink at https://dataq.com/support/downloads/WinDaq-Acquisition-Add-ons-Setup.exe.
Download WinDaq at https://www.dataq.com/support/downloads/DATAQ-Software-Suite-Web-Setup.exe.
Do I get the DI-1100 calibration certificate?
No. All new DI-1100 devices are calibrated but they do not include an NIST-traceable calibration certificate. Consider the DI-2108 if NIST traceability is required.
Can I get the DI-1100 re-calibrated?
Recalibration service is not offered for the DI-1100 as a new device would be less expensive than calibration services. All new DI-1100 devices are calibrated but they do not include an NIST-traceable calibration certificate. Consider the DI-2108 if NIST traceability is required.
Is my sensor compatible with this device?
Maybe. Sensors with an output within the range of ±10 Volts can be used with the DI-1100. See how fine a measurement you can make with your sensor using the ADC Resolution Calculator. If you have any questions about compatibility just send your sensor information to our sales team at sales@dataq.com.
Does the DI-1100 include digital or analog output channels?
No. The DI-1100 has no output channels of any kind.
Specifications
Analog Inputs | |
Number of Channels: | 4 |
Configuration: | Differential |
Full Scale Range: | ±10 V full scale fixed |
Input impedance: | 1MΩ |
Isolation: | none |
Absolute accuracy: | @ 25°C, excluding common mode error ±12.5 mV @ 25°C |
Absolute maximum input without damage: | ±75 V peak, continuous ±100 V peak, one minute or less |
System noise: | 7.8 mV rms |
Maximum common mode voltage: | ± 10 V |
Common mode rejection ratio: | 40 dB (dc - 60 Hz) |
Channel-to-channel crosstalk rejection: | -80 dB |
Digital Inputs | |
Number of ports: | 2 (reserved) |
Type: | MOSFET switch |
Threshold levels: | TTL-compatible |
Absolute maximum applied voltage (V): | ±30 V dc |
Reserved Digital Inputs | |
Port 1: | WinDaq remote events |
Port 2: | WinDaq remote start/stop |
Power | |
Power Consumption: | <1.0 Watt, via USB interface |
ADC Characteristics | |
Resolution: | 12-bit |
Above zero ADC counts: | 2,047 |
Below zero ADC counts: | 2,048 |
Maximum sample rate per channel: | 40 kHz, 1 enabled channel 30 kHz, 2 enabled channels 24 kHz, 3 enabled channels 20 kHz, 4 enabled channels |
Minimum sample throughput: | 915.5 Hz (0.0006104 Hz with WinDaq software) |
Sample rate timing accuracy: | 50 ppm |
Indicators and Connections | |
Interface: | USB 2.0 (mini-B style connector) |
Indicator lights: | 3 LEDs, (2) Green, (1) RGB |
Input Connections: | One 16-position terminal strip |
Environmental | |
Operating Temperature: | 0 to 50 °C |
Operating Humidity: | 0 to 90% RH non-condensing |
Storage Temperature: | -20 to 60 °C |
Storage Humidity: | 0 to 90% non-condensing |
Physical Characteristics | |
Enclosure: | Hardened Plastic |
Mounting: | Desktop; bulkhead |
Dimensions: | 2.625D × 5.5W × 1.53H in. (6.67D × 13.97W × 3.89H cm.) |
Weight: | 3.6 oz. |
Software Support | |
WinDaq software: | OS support |
Programming: | Instrument protocol, ActiveX Control |
Articles
Making Pressure Measurements with the DI-1100
Frequency and True RMS Data Acquisition
Intelligent Oversampling Methods Extend Measurement Flexibility
4-20mA Current Loop Data Acquisition
4-20 mA Measurement Resolution
Videos
Pressure Measurements
Learn how to make pressure Measurements with a pressure sensor and Dataq products.